Residential Heating and Cooling Rebate Eligibility Requirements
Furnace
Natural Gas Furnace 95%+ AFUE
- Must be a customer of a participating electric utility and a participating natural gas utility. Verify your utility
- Customer must use natural gas for home heating.
- Furnace must have an annual fuel utilization efficiency (AFUE) of 95 percent or greater.
- Furnace must meet ENERGY STAR® requirements for U.S. North gas furnaces.
- Only natural gas furnaces are eligible.
- Furnace must be a heating source for the home's living space.
- Chimney liners must be installed where a high-efficiency gas furnace replaces an atmospherically-drafted furnace and only a water heater remains vented through the chimney. The interior opening left by the removed furnace must be closed with a metal cap and sealed with caulk or mortar.
- Be sure to check our pre-qualified equipment list
Boiler
Modulating Natural Gas Boiler 90%+ AFUE
- Must be a customer of a participating natural gas utility. Verify your utility
- Boiler must have an annual fuel utilization efficiency (AFUE) of 90 percent or greater.
- An outdoor-air reset control (integrated) must be installed.
- Boiler must be sealed combustion unit.
- Only natural gas boilers are eligible.
- Boiler must be a heating source for the home's living space.
- Chimney liners must be installed where a high-efficiency gas boiler replaces an atmospherically-drafted boiler and only a water heater remains vented through the chimney. The interior opening left by the removed boiler must be closed with a metal cap and sealed with caulk or mortar.
- Be sure to check our pre-qualified equipment list
- Boiler must meet ENERGY STAR® requirements.
Combination Boiler
Modulating Combination Natural Gas Boiler with Integrated Domestic Hot Water and Outdoor Reset Control, 90%+ AFUE
- Must be a customer of a participating natural gas utility. Verify your utility
- Boiler must have an annual fuel utilization efficiency (AFUE) of 90 percent or greater.
- An outdoor-air reset control (integrated) must be installed.
- Boiler must be sealed combustion unit.
- Boilers must also be a heating source for the home’s living space and domestic water heating source for the home.
- Only natural gas boilers are eligible.
- Chimney liners must be installed where a high-efficiency gas boiler replaces an atmospherically-drafted boiler and only a water heater remains vented through the chimney. The interior opening left by the removed boiler must be closed with a metal cap and sealed with caulk or mortar.
- Be sure to check our pre-qualified equipment list
- Boiler must meet ENERGY STAR® requirements.
Smart Thermostat
- Limit of one rebate per heating system, and two per household.
- Must be a customer of a participating electric utility. Verify your utility
- Home heating source must be provided by a participating utility. Verify your utility Homes heated by LP (liquid propane), oil, electric resistance, or wood are not eligible for the smart thermostat rebate.
- Does not qualify if thermostat services a water heater, ground source heat pump (geothermal), or electric resistance heater.
- Thermostat must be certified as an ENERGY STAR® Connected Thermostat, or meet the following requirements:
- Must be Wi-Fi capable.
- Must be capable of internet connection.
- Must feature occupancy sensing, via geolocation and/or motion sensing.
- The above features must be built-in and not require add-on devices or services.
- The application and connectivity service must be free after thermostat purchase.
- Thermostat default behavior must be to set back temperature when house is unoccupied
- Smart thermostat must be installed to use with the home's primary heating source for the home's living space.
- Only homes heated by a natural gas furnace, natural gas boiler or an air source heat pump are eligible for the smart thermostat rebate.
- Smart thermostat must replace an existing thermostat that does not qualify for program rebates.
- The customer must establish the Wi-Fi connection for program-qualified smart thermostats.
- Be sure to check our pre-qualified equipment list
Electronically Commutated Motor (ECM)
ECM Replacement
- Must be a customer of a participating electric utility. Verify your utility
- Must replace a permanent split capacitor (PSC) blower motor in an existing furnace or air handler.
- Existing furnace must have an annual fuel utilization efficiency (AFUE) of 90 percent or greater.
- Existing furnace must be a sealed combustion unit.
- Furnace must be the primary heating source for the home's living space.
- Be sure to check our pre-qualified equipment list
Heat Pump
Air Source Heat Pump (existing primary heating fuel: propane, oil, etc.)
Must be a customer of a participating electric utility. Verify your utility
Air source heat pump with a minimum of:
- Ducted
- 15.2 SEER2
- 10.0 EER2
- 8.1 HSPF2
- Ductless
- 16.0 SEER2
- 9.0 EER2
- 9.5 HSPF2
- SEER2, EER2, and HSPF2 based on AHRI database, found at ahridirectory.org, for furnace/air handler (if applicable), coil, and condenser.
- System must be listed as "Heat Pumps" and "Variable-Speed Mini-Split and Multi-Split Heat Pumps" within AHRI, "Water-Source Heat Pumps" are not eligible.
- Coil and condenser must be purchased and installed at the same time.
- You cannot receive the rebate for both furnace or boiler and the Air Source Heat Pump.
- Must be primary heating source for the home's living space.
Air Source Heat Pump (existing primary heating fuel: natural gas or electricity)
Must be a customer of a participating electric utility. Verify your utility
Must be a customer of a participating natural gas utility. Verify your utility
Air source heat pump with a minimum of:
- Ducted
- 15.2 SEER2
- 10.0 EER2
- 8.1 HSPF2
- Ductless
- 16.0 SEER2
- 9.0 EER2
- 9.5 HSPF2
- SEER2, EER2, and HSPF2 based on AHRI database, found at ahridirectory.org, for furnace/air handler (if applicable), coil, and condenser.
- System must be listed as "Heat Pumps" and "Variable-Speed Mini-Split and Multi-Split Heat Pumps" within AHRI, "Water-Source Heat Pumps" are not eligible.
- Coil and condenser must be purchased and installed at the same time.
- You cannot receive the rebate for both furnace or boiler and the Air Source Heat Pump.
- Must be primary heating source for the home's living space.
Cold Climate Air Source Heat Pump (existing primary heating fuel: propane, oil, etc.)
Must be a customer of a participating electric utility. Verify your utility
Air source heat pump with a minimum of:
- Ducted
- 15.2 SEER2
- 10.0 EER2
- 8.1 HSPF2
- 1.75 COP at 5 degrees
- Ductless
- 16.0 SEER2
- 9.0 EER2
- 9.5 HSPF2
- 1.75 COP at 5 degrees
- SEER2, EER2, HSPF2, and COP based on AHRI database, found at ahridirectory.org, for furnace/air handler (if applicable), coil, and condenser.
- System must be listed as "Heat Pumps" and "Variable-Speed Mini-Split and Multi-Split Heat Pumps" within AHRI, "Water-Source Heat Pumps" are not eligible.
- Coil and condenser must be purchased and installed at the same time.
- You cannot receive the rebate for both furnace or boiler and the Air Source Heat Pump.
- Must be primary heating source for the home's living space.
Air Source Heat Pump (existing primary heating fuel: natural gas or electric)
Must be a customer of a participating electric utility. Verify your utility
Must be a customer of a participating natural gas utility. Verify your utility
Air source heat pump with a minimum of:
- Ducted
- 15.2 SEER2
- 10.0 EER2
- 8.1 HSPF2
- 1.75 COP at 5 degrees
- Ductless
- 16.0 SEER2
- 9.0 EER2
- 9.5 HSPF2
- 1.75 COP at 5 degrees
- SEER2, EER2, HSPF2, and COP based on AHRI database, found at ahridirectory.org, for furnace/air handler (if applicable), coil, and condenser.
- System must be listed as "Heat Pumps" and "Variable-Speed Mini-Split and Multi-Split Heat Pumps" within AHRI, "Water-Source Heat Pumps" are not eligible.
- Coil and condenser must be purchased and installed at the same time.
- You cannot receive the rebate for both furnace or boiler and the Air Source Heat Pump.
- Must be primary heating source for the home's living space.
Indirect Water Heater
Indirect Water Heater for Home Heating Boiler
- Must be a customer of a participating natural gas utility. Verify your utility
- Must be installed at the same time as a qualified boiler that is also receiving a Focus on Energy rebate.
- Be sure to check our pre-qualified boiler equipment lists at focusonenergy.com/heatingandcooling.
- Indirect water heater rebate is not available with boilers that were previously installed.
Single Package Vertical Unit
- Must be a customer of a participating electric utility and a participating natural gas utility. Verify your utility
- Single package vertical unit must meet the minimum efficiency requirements listed.
- > 90%+ Thermal Efficiency, NG, > 11.0 EER Cooling
- > 90%+ Thermal Efficiency, NG
- Efficiency ratings will be verified using the AHRI database.
- Required features must be documented on a specification sheet.
Package Terminal Heat Pump (PTHP)
- Must be a customer of a participating electric utility. Verify your utility
- Unit must be AHRI listed as a Commercial PTHP.
- Must replace a Packaged Terminal Air Conditioner (PTAC). Replacement of existing PTHP does NOT qualify.
- Window and through-the-wall air conditioners/heat pumps do not qualify.
- The equipment size category (BTUh) is the cooling capacity value of the unit.
- Must meet both heating and cooling specifications for the equipment size category.
- < 8,000 BTUh, > 10.7 EER and > 3.1 COP
- 8,000 - 9,999 BTUh, > 10.4 EER and > 3.0 COP
- 10,000 - 12,999 BTUh, > 9.9 EER and > 2.9 COP
- > 13,000 BTUh, > 9.3 EER and > 2.9 COP
- All efficiency ratings will be verified using the AHRI database.